Trimax Supreme PCP pump (300 bar)
The new Trimax Supreme PCP pump is an excellent choice to get started in PCP, as it will allow you to load your carbine with a very low initial investment.
- Maximum pressure: 300 bar (equivalent to 4500 PSI).
- Recommended for PCP carbines up to 220 bar.
- Number of stages: 3.
- Material: full metal (except for the handle, pressure gauge and O-rings).
- Colour: black stainless steel.
- Hose length: 50cm.
- Integrated humidity filter in the handle.
- Foldable base for stability.
- Connector type: quick connector.
- In the box, in addition to the pump and hose includes:
- Pressure gauge.
- Sealing plug.
- Spare O-rings.
- Moisture filters.
- Dissembly spanner + Allen key + multifuntional tool.
- Dimensions (assembled): 61 cm (height) x 16 cm (width) x 6 cm (depth).
- Total weight: 1900g.
TRIMAX SUPREME PCP PUMP

FILTER HANDLE
The Trimax supreme pump features a handle with a moisture filter, so there is no risk of unwanted particles getting into the pump. This model has several advantages over the rest, it has a folding foot for greater stability and can be easily and conveniently stored anywhere.

TRIMAX PUMP ASSEMBLY
The PCP Trimax pump hardly needs any assembly, just the handles and hose. It also comes with the necessary spanner to assemble and disassemble any part of the pump, as well as spare O-rings, filters and oil to lubricate the system.

INTEGRATED PRESSURE GAUGE
The pressure gauge of the Trimax supreme pump is a main element as it shows the pressure that the pump is picking up at all times. If the carbine has air leaks, this will also be reflected, because the needle will not go up. The ideal is to tighten it as much as possible so that there are no leaks.
TRIMAX PUMP ASSEMBLY INFORMATION
TRIMAX PUMP PROBLEMS AND SOLUTIONS
Problem: If the pressure gauge is not in the correct position or does not rise while the pump is running…
Solution: Check that the gauge is not broken and that it is tightened securely.
Problem: The dipstick is difficult to pull or falls out while pumping…
Solution: Replace small piston o-ring.
Problem: Bounce during down stroke…
Solution: Clean air release valve and valve body o-ring.
Problem: Pressure builds too slowly…
Solution: Check for leaks at: wizard, air filter, connector, bleeder, hose, pressure gauge (soak in water to find the leakage point)

How to use the Supreme Pump properly?
- Do not pump quickly, the maximum frequency is about 50 times per minute.
- The pump creates a lot of pressure, do not close the air outlet when it is running.
- Pressure should not exceed the recommended 4500 psi.
- Pump slowly. Stop at the top and bottom of each stroke to allow air to flow through the entire pump.
- Do not let it run all the way to the end of each stroke.
Recommendations and maintenance
- Do not pump for more than 5 minutes, leave the pump for 15 minutes to cool down after each period.
- Open the bleed screw to relieve pressure in the hose, keep the Trimax pump at pressure. De-aerate when not in use.
- Keep the pump dry and clean, ideally indoors away from extreme temperatures.
- The pump needs oil refilling after approximately 800 strokes. Put three drops in the top handle and a few drops in the secondary pipe.
Trimax Supreme PCP pump (300 bar)
Q & A
Trimax Supreme PCP pump (300 bar)

































Reviews
There are no reviews yet